EN

Knowledge

KEF, CEF, CYJY: Reading Shipboard Cable Codes to IEC 60092

Shipboard cable codes to IEC 60092 and GB/T 9331/9332 read left to right through fixed positions: K marks a rubber control cable and C a ship power cable, E or G selects EPR or silicon rubber insulation, F or H selects a CR or CSM sheath, and trailing letters add P for a copper braid shield and R for a flexible conductor.

Shipboard cable serves on board vessels, offshore oil platforms and offshore buildings, feeding control, instrument, meter, monitoring and protection circuits, plus power supplies and inverter drives, all in a humid environment. The Chinese shipboard catalogue is built to IEC 60092 with GB/T 9331 and GB/T 9332 as the national pairings, and its designations — KEF, KEFRP, CEF, CYJY, CEFR84 — are assembled by position. Once the positions are learned, any code in the catalogue can be expanded into its full construction without a lookup table.

KEF80 shipboard cable code anatomy split into K control, E EPR insulation, F CR sheath, 8 copper braid armour and 0 no outer sheath

How the code is assembled

The naming rules define seven positions: (1) an addition prefix for special properties, (2) the product mark, (3) the conductor kind, (4) the insulation material, (5) the sheath material, (6) the armour, and (7) the outer sheath over the armour. The control scheme and the power scheme use the same skeleton with slightly different letters. The catalogue’s worked example for the control scheme spells a complete designation piece by piece: ZWD-K-E-F-8-2, 150/250 V, 37 cores of 2.5 mm² — a flame-retardant, low-smoke control cable carrying EPR insulation, CR sheath, copper wire braid armour and a PVC outer sheath, with W the halogen-free addition as defined in the power-scheme property letters.

Naming positions — shipboard cable designation letters
LetterMeaningAppears in
KRubber control cableKEF, KEFR, KEFP, KEFRP
CShip power cableCEF, CEFR, CYJY, CYJYP
BStranded conductor (omitted from the code)Implied in all non-R types
RSoft (flexible) conductorKEFR, CEFR, CYJYR
EEPR: ethylene-propylene rubber insulationKEF, CEF, CEH
GSilicon rubber insulationKGF, KGHP
YJXLPE: crosslinked polyethylene insulationCYJY, CYJYR, CYJYP
FCR: chloroprene rubber sheathKEF, CEF, KEF80
HCSM: chlorosulfonated polyethylene sheathKEH, CEH, KGH
YPE: polyethylene sheath (power scheme)CYJY
PCopper braid shieldKEFP, CEFP, CYJYP, KEFRP
8 / 9Copper / steel wire braided armourKEF80, CEF90 (see the armour article)
Z/ZR, N, W, DAddition prefix: flame retardant, fire safe, halogen free, low smokeZWDKEF82

The control family: K first

Every type in the control family starts with K. Four insulation-and-sheath combinations cover the stranded versions — EPR or silicon rubber insulation, CR or CSM sheath — and the suffixes add the flexible conductor, the braid shield, or both. Representative rows from the type table:

Shipboard control cable types (selected)
TypeConductorCatalogue name
KEFstrandEPR insulated CR sheathed ship control cable
KEHstrandEPR insulated CSM sheathed ship control cable
KGFstrandSilicon rubber insulated CR sheathed ship control cable
KGHstrandSilicon rubber insulated CSM sheathed ship control cable
KEFRsoftEPR insulated CR sheathed ship control flexible cable
KEFPstrandEPR insulated copper braid shield CR sheathed ship control cable
KEFRPsoftEPR insulated copper braid shield CR sheathed ship control flexible cable
KGHRPsoftSilicon rubber insulated copper braid shield CSM sheathed ship control flexible cable

Two voltage grades cover this family, and the grade determines the standard pair: 150/250 V cable is manufactured according to IEC 60092-353:1995 & GB/T 9331-2008, while 0.6/1 kV cable is manufactured according to IEC 60092-376:1995 & GB/T 9332-2008. The KEF / KEFP control series and the KEFR / KEFRP flexible control series carry both grades with full dimension tables.

KEFP shipboard control cable cross-section with seven copper cores, EPR insulation, copper braid shield and CR sheath

The power family: C first — CEF, CEH, CYJY

The power scheme mirrors the control scheme with C for ship cable, and it adds two letters the control scheme does not use: YJ for XLPE insulation and Y for a PE sheath. CEF, CEFR, CEFP and CEFRP follow the EPR/CR pattern; CEH types take the CSM sheath; and CYJY is the XLPE insulated, PE sheathed construction. The full power table lists sections from 1.5 to 300 mm² at a conductor temperature of 85°C:

Shipboard power cable types (selected, sections 1.5–300 mm², 85°C)
TypeConductorCatalogue name
CEFstrandEPR insulated CR sheathed ship cable
CEFRsoftEPR insulated CR sheathed ship flexible cable
CEFPstrandEPR insulated copper braid shield CR sheathed ship cable
CEFRPsoftEPR insulated copper braid shield CR sheathed ship flexible cable
CEHstrandEPR insulated CSM sheathed ship cable
CYJYstrandXLPE insulated PE sheathed ship cable
CYJYRsoftXLPE insulated PE sheathed ship flexible cable
CYJYPstrandXLPE insulated copper braid shield PE sheathed ship cable

Armoured and sheathed-over-armour versions extend both families — CEF80/90, CEF83/93 and CEFR84/94, with CYJY equivalents — which are decoded in the companion article 80, 83, 90, 94: What the Numbers on Armoured Shipboard Cable Mean. The power types are also built as convert (variable-frequency) cables for inverter-driven deck machinery, listed in the CEF convert / variable-frequency series.

Worked examples: reading real designations

Three designations, expanded letter by letter, show the system at work. KEFRP is a rubber control cable (K) with EPR insulation (E), CR sheath (F), soft conductor (R) and copper braid shield (P) — the flexible, screened control cable for mobile indoor use. CYJYP is a ship power cable (C) with XLPE insulation (YJ), PE sheath (Y) and copper braid shield (P). ZWDKEF82 prefixes the control scheme with the addition properties — flame retardant and low smoke, with W the halogen-free addition as defined in the power-scheme property letters — then reads K (control), E (EPR), F (CR sheath), 8 (copper wire braid armour) and 2 (PVC outer sheath): the catalogue’s example is rated 150/250 V in 37 cores of 2.5 mm².

Voltage classes, temperature limits and bending radii

Two voltage grades dominate the shipboard catalogue — 150/250 V and 0.6/1 kV for control, 0.6/1 kV and 1.8/3 kV for power — and the using properties fix the rest of the envelope:

Using properties — shipboard cables to IEC 60092 / GB/T 9331 & 9332
PropertyRequirement
Rated voltage U0/U150/250 V or 0.6/1 kV (control); 0.6/1 kV or 1.8/3 kV (power)
Voltage withstand test3.5 × U0 for 5 min, without puncture
Operating temperatureAmbient not lower than −10°C; conductor not above 85°C (power types listed at 85/90°C)
Minimum working bending radius — control (150/250 V KEF types)≥4×D (D≤25 mm), ≥6×D (D>25 mm)
Minimum working bending radius — power (CEF/CYJY types)≥4×D unarmoured, ≥6×D armoured or shielded
LayingR types (KEFR, CEFR, KEFRP, CEFRP) for soft, indoor mobile requirements; other types mainly for fixed laying

The 150/250 V control grade pairs with IEC 60092-353 / GB/T 9331, the 0.6/1 kV grade with IEC 60092-376 / GB/T 9332, and ship power cable with IEC 60092-353 / GB/T 9331 — the same dual-standard approach described for rubber cable in IEC 60245 vs GB/T 5013. The voltage notation itself is unpacked in From 300/300 V to 8.7/10 kV.

Choosing within the families

Selection reduces to four questions. Control or power (K or C)? Insulation elastomer for the thermal and electrical duty (E EPR, G silicon rubber, YJ XLPE)? Sheath for the environment (F CR, H CSM, Y PE)? Flexible or fixed (R or not), screened or not (P or not), armoured or not (two trailing digits or none)? The marine & shipboard cable category organises the series along exactly these lines, the CEF / CEFP power series carries the power dimension tables, and the RFQ desk answers code questions against your cable schedule — samples of the standard series are available for evaluation, and small orders start at 500 m.

FAQ

Shipboard Cable Codes — Quick Answers

C is the ship power cable mark, E is EPR (ethylene-propylene rubber) insulation, and F is a CR (chloroprene rubber) sheath — so CEF is the EPR insulated, CR sheathed ship power cable. Changing the sheath letter to H gives CEH with a CSM (chlorosulfonated polyethylene) sheath, and changing the insulation block to YJ gives CYJY with XLPE insulation under a PE sheath.
The R marks a soft (flexible) conductor. Per the using properties, KEFR-type flexible cables are used for the soft occasions of indoor mobile requirements, while the stranded non-R types mainly serve fixed laying. The same distinction runs through the power family: CEF for fixed runs, CEFR where the cable moves.
P adds a copper braid shield — the catalogue names KEFP as the “EPR insulated copper braid shield CR sheathed ship control cable”. On shipboard systems that shield is specified for the control, instrument, meter, monitoring and protection circuits, where the circuits must keep working cleanly beside power feeds and drives in a humid environment.
All three are cited together, in pairs by voltage grade: 150/250 V cable is manufactured according to IEC 60092-353:1995 & GB/T 9331-2008, and 0.6/1 kV cable according to IEC 60092-376:1995 & GB/T 9332-2008. Ship power cable follows the IEC 60092-353 / GB/T 9331 pairing, so a single construction is documented against both the IEC and the GB designation.
Yes — the positions stack. The catalogue’s worked example ZWDKEF82 combines the ZWD addition prefix, K control scheme, EPR insulation, CR sheath, 8 copper wire braid armour and 2 PVC outer sheath in one 150/250 V, 37×2.5 mm² cable. The armour digits are decoded fully in 80, 83, 90, 94: What the Numbers on Armoured Shipboard Cable Mean.

Shipboard Sourcing

Send us your cable list — even for 500 m.

Codes, voltage grades, core counts: our engineers read the designation against IEC 60092 and GB/T 9331/9332, and revert with a quotation, a sampling plan and the class documentation route. Standard KEF and CEF series start at 500 m per item; urgent orders are scheduled against your outfitting window.

Send Your Drawing Browse Shipboard Cables